Developer's Design Engineer submits plans for review with all applicable
reference materials as delineated on the Plan
Check Submittal Requirements plan checking submittal requirement
sheets to the Land Development Section of the Engineering Division. For
more information call the Land Development Section at, (408) 586-3325.
The plan check and inspection deposit shall be deposited into an Private Job Account (PJ).
The City Plan Check Engineer forwards the appropriate submittals to the
appropriate reviewing staff ( Fire Dept., P.W. Maintenance, Design Sec.,
Utility Sec.) to initiate detailed plan check.
Prior to completion of first plan check and all subsequent plan checks,
the Plan Check Engineer will resolve any potential conflicting comments
and return one set of check prints to the Developer's Design Engineer.
The assigned City Plan Check Engineer verifies that the affected
agencies are reviewing the plans.
If the Design Engineer wish to discuss any of the comments, he/she can
call to review comments or can request a meeting with the Plan Check
Engineer.
Reviews required by Other Agencies such as
Santa Clara Valley Water District, Utility Companies and Caltrans may have
different plan check turnaround times than the City. Plan checks may
proceed without input from all agencies; however, prior to the final
approval input from all agencies shall be reviewed by City and all
appropriate comments and plan modifications of other agencies shall be
addressed and incorporated into the plans. It is the Design Engineer's
responsibility to coordinate other agencies plan check which may be
affected by the project or have an affect on other projects.
All subsequent plan checks shall be submitted to the assigned Plan Check
Engineer and shall include prior check prints and comments.
The Design Engineer shall make corrections to improvement plans, maps,
reports and calculations according to the Engineering plan check reviews.
A complete set of previous check print markups along with 3 sets of
corrected prints shall be resubmitted to the Land Development section of
the Engineering Division .
The second plan check submittal by the Design Engineer shall include
updated construction cost estimates and an indication of the type of
security ( surety, letter of credit, cash, account assignment) to be used.
The Plan Check Engineer shall verify construction quantities and determine
the bond, fees, and prepare the subdivision improvement agreement. The
agreement and security shall be 100% of the cost of public improvements
for faithful performance and 100% of the cost of public improvements for
labor and materials.
Upon completion of the plan checking process (including other agencies'
review as applicable), the Plan Check Engineer will direct the Design
Engineer to transmit to the Land Development Section of the Engineering
Division an original mylar of the map, improvement plans and other reports
for the City Engineer's approval.
Following the Plan Check Engineer's recommendation for plan approval the
original plans will be routed for final review and approval by:
Fire Department.
Land Development Engineer.
City Engineer.
The subdivision map and public improvement agreement will be schedule
for City Council action upon the completion of the following:
Subdivision agreements (signed and notarized).
Easements and other agreements are signed and submitted.
Conditions of approval.
Subdivision map will be submitted to City Clerk and City Engineer for
signatures upon completion of the following:
Deposits and fees (paid)
All bonds (submitted).
Subdivision guarantee (submitted).
All conditions of approval (satisfied).
City Council approval of Subdivision Agreement, Public Improvement
Drawings and Final Map.
After the City Clerk and City Engineer approvals (signatures), the
subdivision map and easements (if applicable). Final map will be released
to the title insurance company for recordation processing.
The Plan Check Engineer will notify the Design Engineer that the plans
have been approved and will transmit the originals plans for prints and in
house filling.
Prints of plans needed by the Design Engineer and owner for contract
bidding and construction shall be required through a bonded blue print
company. The Plan Check Engineer will submit the approved set of plans to
the blue print company upon direction by the Design Engineer.
Construction permits will be issued only after appropriate plans are
signed, public improvement agreement executed and bonded for, and fees and
deposits paid.
The City Engineering Division will concur with approval of the building
permits after subdivision maps are recorded, all conditions are met, and
all permit fees are paid.
Once all public facilities have been constructed, survey monumentation
have been set and record drawing have been submitted, the City Council
adopts a Resolution initially accepting the project. The faithful
performance's security is reduced to 10% of its original value for the
warranty period and released upon final acceptance. The labor and
materialmen's security is reduced to an amount equal to the total amount
claimed by all claimants for whom claims of lein have been recorded and
written notice have been given to the City Clerk (if any), if no claim
have been received, the security will be released in full ninety (90) days
after initial acceptance. For a one year period, the developer is
responsible for the repair and replacement of any public improvement
deficiencies. The consulting engineer provides City with a letter of
monumentation certificate upon completion of monument placement.
If the project is found to be completed upon final inspection, the City
Council adopts a resolution finally accepting the project one-year after
initial acceptance and the remainder of the security is then released.
List of other Agencies
City of Fremont
39550 Liberty Street, Fremont, CA 94537-5006
(510) 494-4445
City of San Jose
801 North 1st Street, San Jose, CA 95110
(408) 277-5161
Comcast Business and Engineering Services
Phone 1-800-984-2824
Fax (925) 443-0123
PG&E, Planning Division
111 Almaden Blvd., Room 814, San Jose, CA 95115-005,
(408) 282-7543
San Jose/Santa Clara Water Pollution Control Plant
700 Los Esteros, San Jose, CA 95134
(408) 945-5307
Santa Clara County Road and Airports
101 Skyport Drive, San Jose, CA 95110
(408) 573-2462
Santa Clara Valley Transportation Authority
3331 N First St, Building B, San Jose, CA 95134-1906
(408) 321-2300
Santa Clara Valley Water District
5750 Almaden Expwy, San Jose, CA 95118
(408) 265-2600
San Francisco Public Utility Commission,
(Hetch Hetchy Water System Operation)
1000 El Camino Real, Millbrae. CA 94030
(650) 872-5900
SBC South Bay Engineering Division
3475B North First St. Room 200
San Jose, CA 95134
Phone (408) 493-7090
Fax (408) 493-9547
State of Calif. Department of Health Services
2151 Berkeley Way, Room 458, Berkeley, CA 94704-1011
(510) 540-2413
State of Calif. Department of Transportation (Caltrans)
500 Quince Lane, San Jose, CA 95112
(408) 452-713
State of Calif. Department of Water Resources
3251 S Street, Sacramento CA 95818
(916) 227-7585